Standby generators / 14 kW

14 kW standby generator: what it runs and what it burns

Generac's 14 kW Guardian is rated 14 kW on propane and 14 kW on natural gas. At full load it burns 3.07 gallons of propane an hour (1.81 at half load), so 100 gallons lasts about 32.6 hours at full load and 55.2 hours at half load.

Propane rating
14 kW
Natural gas rating
14 kW
Propane, full load
3.07 gal/h
Natural gas, full load
256 ft³/h
Refrigerator/freezer ×1: 700 WSump pump, 1/2 hp ×1: 1,050 WFurnace fan blower, 1/3 hp ×1: 700 WWell pump, 1/2 hp ×1: 1,000 WCPAP machine (ResMed AirSense 11) ×1: 73.2 WLED light bulb, 15 W ×6: 90 WCell phone charger ×2: 40 WTelevision, LED ×1: 80 WLaptop ×1: 60 WMicrowave, 1,000 W ×1: 1,000 WCoffee maker ×1: 1,500 WElectric water heater ×1: 4,500 WDesktop computer with monitor ×1: 800 WRunning 11,593.2 W+ 2,200 W start = 13,793.2 Wnatural gas rating 14,000 Wpropane rating 14,000 W
A whole-home list the 14 kW carries on natural gas in this site's order, to scale; the cap is the biggest starting surge.

The 14 kW is the one Guardian size Generac rates the same on both fuels: 14 kW on propane and 14 kW on natural gas. Generac's sizing page says a 10 to 14 kW unit with one or two load managers can prioritize the air conditioner and well pump, switching big loads off while others run.

What it carries

Filling a whole-home list in a fixed order — essentials first (refrigerator, sump pump, furnace fan, well pump, CPAP, lights, electronics, microwave, coffee maker), then central air (2 ton), an electric water heater, a range element, washer, dishwasher, garage door and a desktop computer — and adding the single biggest starting surge to the running total as Generac's formula does, the 14 kW on natural gas carries 11,593.2 W running with a 2,200 W surge on top, 13.8 kW of its 14 kW. It has to leave out: Central air conditioner, 24,000 BTU (2 ton), Electric range, one 8-inch element, Washing machine, Dishwasher, Garage door opener, 1/2 hp. On propane it carries 11,593.2 W running, 13.8 kW with the surge.

Load (natural gas list)QtyRunning WExtra to start
Refrigerator/freezer17002,200
Sump pump, 1/2 hp11,0502,150
Furnace fan blower, 1/3 hp17001,400
Well pump, 1/2 hp11,0002,100
CPAP machine (ResMed AirSense 11)173.2—
LED light bulb, 15 W690—
Cell phone charger240—
Television, LED180—
Laptop160—
Microwave, 1,000 W11,000—
Coffee maker11,500—
Electric water heater14,500—
Desktop computer with monitor1800—

Central air with the basics alone needs 9.6 kW by the brochure figures — inside this unit's natural gas rating. Generac's sizing page warns that a 3-ton system "typically requires about 3.5kW to 5kW of running wattage" and can need 15 to 18 kW to start, far more than the brochure's 2-ton row; check the compressor's locked-rotor amps with an installer.

Fuel use

FuelHalf load, per hourFull load, per hourHalf load, per dayFull load, per day
Propane (gallons)1.813.0743.473.7
Natural gas (cubic feet)1952564,6806,144
1.48103.07143.02183.74203.9223.9243.6326
Propane burned at full load, gallons per hour, for each Generac Guardian size (kW on the axis). From Generac's fuel table.

Half load burns 59% as much propane as full load, not 50%, so halving the load does not double the run time. Per-day figures assume the load holds steady for 24 hours; a real outage swings between the two. Generac's continuous-use guidance asks for a shutdown of at least 30 minutes after every 24 hours of running. The propane run-time guide works through a tank.

Fuel: Generac Support, How much fuel does my home standby generator use (Guardian Series table, Feb 12, 2026). Ratings: Generac Guardian 10/14/18 kW spec sheet.

Altitude and heat

Generac's spec sheet: "Maximum power decreases approximately 3.5% for each 1,000 ft (304.8 m) above sea level and approximately 1% for each 10 °F (6 °C) above 60 °F (16 °C)." At 5,000 feet that leaves 11.6 kW on natural gas and 11.6 kW on propane; on a 100 °F day at sea level, 13.4 kW and 13.4 kW. The calculator applies both when it picks a size, and the derating guide has a full table.

Smaller: 10 kW (9 kW on natural gas). Larger: 18 kW (17 kW on natural gas). Installation needs a transfer switch, a gas supply sized for full load, and the clearances in the installation manual.