What will it run / 5,000 W
What will a 5,000 watt generator run?
Taking the Westinghouse iGen5000 as the example: it is rated 3,900 W running and 5,000 W peak. In this site's outage order it carries 8 kinds of load at once — 2,793.2 W running, with room to start the biggest motor in the list for a total of 4,993.2 W — and it can start 26 of the 30 devices in the tables on their own.
Westinghouse sells the iGen5000 on its 5,000 W peak figure; its running rating is 3,900 W. That gap of 1,100 W is the room it has for a starting surge once the running load reaches its rating.
Westinghouse lists 18 hours of run time at 25% load from its 3.4-gallon tank.
An outage list it can carry
| Load | Qty | Running W | Extra to start |
|---|---|---|---|
| Refrigerator/freezer | 1 | 700 | 2,200 |
| Sump pump, 1/2 hp | 1 | 1,050 | 2,150 |
| Furnace fan blower, 1/3 hp | 1 | 700 | 1,400 |
| CPAP machine (ResMed AirSense 11) | 1 | 73.2 | — |
| LED light bulb, 15 W | 6 | 90 | — |
| Cell phone charger | 2 | 40 | — |
| Television, LED | 1 | 80 | — |
| Laptop | 1 | 60 | — |
| Total | 2,793.2 | + 2,200 = 4,993.2 |
The list is filled in a fixed order — refrigerator, sump pump, furnace fan, well pump, CPAP, lights and chargers, then television, laptop, microwave, coffee maker, space heater and window air conditioner — skipping anything that would push the running total past 3,900 W or the starting total past 5,000 W. It leaves 1,106.8 W of running capacity and 6.8 W of starting capacity unused. The highlighted row has the biggest starting surge, which is the one added to the running total.
What it can start on its own
Refrigerator/freezer; Sump pump, 1/3 hp; Sump pump, 1/2 hp; Well pump, 1/3 hp; Well pump, 1/2 hp; Furnace fan blower, 1/3 hp; Furnace fan blower, 1/2 hp; Garage door opener, 1/2 hp; Microwave, 1,000 W; Coffee maker; Toaster; Toaster oven; Air fryer; Slow cooker; Electric range, one 8-inch element; Dishwasher; Washing machine; Space heater; CPAP machine (ResMed AirSense 11); Oxygen concentrator (Philips EverFlo); LED light bulb, 15 W; Television, LED; Laptop; Desktop computer with monitor; Cell phone charger; AM/FM radio.
Too big even alone: Window air conditioner, 12,000 BTU (7,200 W to start); Central air conditioner, 24,000 BTU (2 ton) (8,750 W to start); Heat pump (9,200 W to start); Electric water heater (4,500 W to start).
A refrigerator and a 1/2 hp sump pump together need 1,750 W running and 3,950 W to start — within this generator's ratings.
Compared with the other sizes
Run time: 18 hours at 25% load from a 3.4-gallon tank, by the maker's figures. Keep it outdoors at least 20 feet from doors, windows and vents (why).
Ratings: Westinghouse, iGen5000 inverter generator. Appliance figures: Generac GP brochure, EWEB and Champion tables (see methodology). Other sizes: 2,200 W · 3,000 W · 7,000 W · 7,500 W · 9,500 W.