Generator size by appliance / oxygen concentrator
What size generator runs an oxygen concentrator
Oxygen concentrator (Philips EverFlo): 350 W running with no starting surge in the source table, so a generator needs 350 W of running capacity for it. The smallest of the six portables this site covers that can do it is the Honda EU2200i (1,800 W running, 2,200 W max).
Philips lists the EverFlo stationary concentrator at an average power consumption of 350 W. Other concentrators differ; the figure on your unit's label is the one to use.
A concentrator is a life-support device for many users, so a generator is a backup, not a plan on its own. Keep backup oxygen as the supplier directs.
The generator must sit outdoors at least 20 feet from doors, windows and vents; an extension cord brings the power inside.
The figures and where they come from
| Device | Source | Running W | Additional starting W | Starting need alone |
|---|---|---|---|---|
| Oxygen concentrator (Philips EverFlo) | Philips EverFlo brochure | 350 | — | 350 |
Highlighted rows are the figures the calculator uses. Every table here prints additional starting watts: the surge on top of running watts. Average power consumption.
Which portables can run it
| Generator | Running / peak W | Alone | With fridge, 6 LED bulbs, 2 chargers |
|---|---|---|---|
| Honda EU2200i | 1,800 / 2,200 | Yes | No |
| Honda EU3000iS | 2,800 / 3,000 | Yes | No |
| Westinghouse iGen5000 | 3,900 / 5,000 | Yes | Yes |
| Honda EU7000iS | 5,500 / 7,000 | Yes | Yes |
| Champion 201040 | 7,500 / 9,375 | Yes | Yes |
| Westinghouse WGen9500DF | 9,500 / 12,500 | Yes | Yes |
A generator fits when its running rating covers every running watt and its peak (or "max") rating covers the running total plus the single biggest starting surge. Adding the basics — a refrigerator (700 W running, 2,200 W to start), six 15 W LED bulbs and two phone chargers — raises the running load to 1,180 W and the starting need to 3,380 W, because the refrigerator's surge is now the biggest one. The smallest portable here that covers that is the Westinghouse iGen5000.
On a standby generator
A home standby unit is rated in kilowatts and has no overload capacity: Generac's rating definition says "No overload capability is available for this rating." Using Generac's own formula — sum of running watts plus the highest single starting burst — the oxygen concentrator with the basics needs 3.4 kW. The smallest Guardian model that covers it on natural gas is the 10 kW, rated 9 kW on natural gas and 10 kW on propane, which leaves 5.6 kW of starting room for everything else. Whole-home lists are on the standby generator pages.
Before running anything, read the carbon monoxide distance rules and how a transfer switch keeps power off the utility lines. Other appliances: refrigerator · sump pump · well pump · furnace · window AC · central air · heat pump · space heater · water heater · washing machine · garage door opener · CPAP · .